The Universal PCXR4 personal or area air sampling pump features a 5 to 5000 ml/min flow range, timer, flow fault, and up to 12-hour run times for sampling particulates and gases/vapors. The pump is ideal for use with sorbent tubes, filter cassettes, size-selective samplers, sample bags, and impingers.
The Universal PCXR4 air sampling pump is UL Listed for intrinsic safety.
Specifications
Performance Profile
Operating Range
|
1000 to 5000 ml/min (UL Listed model) (5 to 500 ml/min requires the 224-26 Series adjustable tube holder) Requires 1/4-inch ID tubing
|
Weight
|
34 oz (964 gm) |
Dimensions
|
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
Compensation Range
|
1000 to 2500 ml/min at 40 inches water back pressure 3000 ml/min at 35 inches water back pressure 4000 ml/min at 20 inches water back pressure 5000 ml/min at 10 inches water back pressure |
Typical Back Pressure
|
See Table 1. |
Flow Control
|
Holds constant flow to ± 5% of set-point |
Run Time: Battery
|
NiCad Battery: 8 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 3 NiMH Battery: 12 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2. Battery Eliminator: Pump provides extended runs. |
Run Time: Mains Adapter
|
9999 minutes (6.8 days). Pump will shut off as run time cannot exceed timer display. See Timer Display Range below. |
Tubing |
Requires 1/4-inch ID tubing |
Timer Display Range
|
1 to 9999 minutes (6.8 days). Pump will shut off at 9999 minutes. To reset, restart the pump. |
Flow Indicator
|
Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min |
Power Supply
|
6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity or 6.0-V plug-in NiCad battery pack, rechargeable, 2.0-Ah capacity A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety.
|
Charging Time (varies with battery capacity and level of discharge)
|
6 to 8.5 hrs with PowerFlex Charger |
Intrinsic Safety
|
UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C ATEX-approved model is available. Contact SKC
|
Operating Temperature
|
32 to 104 F (0 to 40 C) |
Storage Temperature
|
-4 to 113 F (-20 to 45 C) |
Charging Temperature
|
50 to 113 F (10 to 45 C) |
Operating Humidity
|
0 to 95% non-condensing |
Flow Fault
|
If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault. During flow fault, the pump stops, displays FLOW FAULT, pauses timing functions, and displays elapsed time. Auto-restart is attempted up to 5 times. |
Low Battery Fault
|
Pump stops, displays LO BATT, pauses timing functions, and displays elapsed time. |
Battery Test
|
LCD indicator verifies battery condition prior to sampling. |
Time Display
|
LCD displays up to 9999 minutes (6.8 days) at which point the display rolls over to 0. |
Timing Accuracy
|
± 0.05% (± 45 sec/day) |
Sampling Pause (Hold)
|
Allows user to temporarily halt air sampling without loss of timing data. Restart does not require resetting time. |
Multiple-tube Sampling
|
Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable tube holder accessory |
RFI/EMI Shielding
|
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1 Frequency range of the radiated susceptibility test was 27 to 1000 MHz CE marked |
Additional Specifications
|
Built-in fluid/particulate trap External see-through filter housing Tamper-resistant control cover Tamper-resistant compensation adjustments Built-in accessory mount Stainless steel belt clip External exhaust port All non-plastic parts made of corrosion-resistant materials RFI and EMI-shielded case |
Additional Features
|
One-year warranty Ultra-quiet operation Pulsation-free flow Impact-resistant case |
Protect sample pump from weather when in use outdoors.
Documentation
PCXR4 Operating Instructions (PDF)
PCXR4 Spec. Sheet (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
Battery Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)
SDS for Nickel Cadmium Battery UL & MSHA models (PDF)
SDS for Nickel-metal Hydride Battery (PDF)
UL Certificate of Intrinsic Safety
EC Declaration of Conformity (PDF)
EU Declaration of Conformity for Universal 224-44MTX, 224-44PCMTX4, 224-44PCMTX8 (PDF)
EU Declaration of Conformity 223-203A,-223A,-227A,-229A,-230A,-239A NiCD/NiMH Battery Chargers (PDF)
EU Declaration of Conformity 223-102A,-103A,-105A,-106A,-107A,-109A NiCD/NiMH Battery Chargers (PDF)
EU Declaration of Conformity 223-300B,-300C,-305B,-305C,-320B,-320C,-325B,-325C,-330B,-330C AC Adapter (Battery Eliminator) (PDF)
Instrucciones de Operación PCXR4 (PDF)
Bedienungsanleitung PCXR4 (PDF)
Mode d’emploi Pompe de prélèvement universelle PCXR4 (PDF)
Pumps
Universal PCXR4 Sample Pump Universal PCXR4 Pump only with timer and flow fault, NiMH battery, and screwdriver set; charger not included Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4 |
Universal PCXR4 Sample Pump Without Battery Universal PCXR4 personal sample pump with timer and flow fault only, battery and charger not included Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4NB |
Kits
Universal PCXR4 5-pack Sample Pump Kit High/Low Flow 5-Pack Universal PCXR4 Pump Kit with five each: pumps with timer and flow fault, NiMH battery, screwdriver sets, filter cassette holders, low flow holders with Type A tube cover, and exhaust port fittings; one 5-station charger (100-240 V), and carry case Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4K5D |
Universal PCXR4 Single Sample Pump Kit High/Low Flow Universal PCXR4 Single Pump Kit includes pump with timer and flow fault, NiMH battery, screwdriver set, 100-240 V single charger, filter cassette holder, low flow holder with Type A tube cover, exhaust port fitting, and carry case Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4KD |
Universal PCXR4 Single Sample Pump Kit High/Low Flow Universal PCXR4 Single Pump Kit includes pump with timer and flow fault, NiMH battery, screwdriver set, 100-240 V single charger, filter cassette holder, low flow holder with Type A tube cover, exhaust port fitting, and Pelican carry case Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4KDH |
Universal PCXR4 Single Sample Pump Kit with IOM Universal PCXR4 Single Pump Kit with IOM Sampler includes sample pump with timer and flow fault, NiMH battery, screwdriver set, 100-240 V single charger (does not include filter cassette holder), low flow holder with Type A tube cover, exhaust port fitting, IOM Sampler and Cassette Cat. No. 225-70A, and carry case Flow range: Constant flow 5 to 5000 ml/min |
224-PCXR4PK |
Universal PCXR4 Sample Pump Starter Kit Universal PCXR4 Pump Starter Kit with NiMH battery, 100-240 V charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie Flow range: Constant flow 5 to 5000 ml/min Low flows from 5 to 500 ml/min require adjustable low flow holder. UL approved for intrinsic safety |
224-PCXR4-S |
Accessories
AC Adapter (Battery Eliminator), for Universal Pumps, 115 V AC Adapter (battery eliminator), 115 V, for Universal Pumps, for extended run times Use of the battery eliminator voids the UL Listing for intrinsic safety. |
223-325 |
AC Adapter (Battery Eliminator), Universal Pumps, 230 V AC Adapter (battery eliminator), 230 V, for extended run times Use of the battery eliminator voids the UL Listing for intrinsic safety. |
223-325B |
Carry Case, Pelican, for 5-pack Universal XR Pump Kits 5-pack Kit Carry Case, for Universal XR Series pumps, watertight, airtight, dustproof, and crushproof, equipped with foam for complete equipment protection |
224-908 |
PowerFlex 5-station Battery Charger, 100-240 V PowerFlex® 5-station Battery Charger, 100-240 V, includes power supply and cord; for use with all SKC NiCad or NiMH battery powered air sampling pumps; purchase pump-specific cables separately from the following list: Cat. No. 223-1001 for AirChek 2000, Cat. No. 223-1002 for Universal (5-cell), Cat. No. 223-1003 for Universal (4-cell, MSHA), Cat. No. 223-1004 for AirChek 52, and Cat. No. 223-1005 for 222 Series Low Flow For U.S.-produced pump models only, not compatible with EX and ATEX-approved models |
223-1000 |
PowerFlex Cable, for Universal XR (5-cell) Series Pumps PowerFlex® Cable, for use with PowerFlex Single or Multi-Chargers, for Universal XR (5-cell) Series air sampling pumps only, 1 cable |
223-1002 |
PowerFlex Single Battery Charger, 100-240 V PowerFlex® Single battery charger, 100-240 V, includes power supply and cord; purchase pump-specific cables(s) separately from the following list: Cat. No. 223-1001 for AirChek 2000, Cat. No. 223-1002 for Universal (5-cell), Cat. No. 223-1003 for Universal (4-cell, MSHA), Cat. No. 223-1004 for AirChek 52, and Cat. No. 223-1005 for 222 Series Low Flow For U.S.-produced pump models only, not compatible with EX and ATEX-approved models |
223-2000 |
Protective Nylon Pump Pouch, for Universal PCXR and XR Pumps Protective Nylon Pump Pouch, for Universal PCXR and XR pumps, red, with belt and adjustable waist and shoulder strap |
224-95A |
Replacement Ni-Cad Battery Pack, for Universal PCXR and XR Series Pumps Replacement Ni-Cad Battery Pack, for Universal PCXR and XR Series Pumps only, ea Not suitable for MSHA-approved models Replacing batteries with non-approved battery packs voids the pump warranty and UL listing for intrinsic safety. |
P21661 |
Replacement NiMH Battery Pack, for Universal Series PCXR and XR Series Pumps Replacement NiMH Battery Pack, for Universal Series PCXR and XR Series Pumps only, ea Not suitable for MSHA-approved models Replacing batteries with non-approved battery packs voids the pump warranty and UL listing for intrinsic safety. |
P21661MH |
Tygon Tubing Tygon Tubing, 1/4-inch ID x 3/8-inch OD,fits over impinger side arm, impinger inlet, filter cassette outlet, or Luer adapter. 50 feet |
225-1345 |
Universal Pump Nylon Pouch, Black Protective Nylon Pump Pouch, for Universal PCXR and XR pumps, black with SKC Logo, with belt and adjustable waist and shoulder strap |
224-87 |