Flow range of 1000 to 3000 ml/min
Ideal for most personal sampling applications including sorbent tubes, filter cassettes, impingers, and size-selective samplers, and long-duration detector tubes; high flow range of 1000 to 3000 ml/min; low flow range of 5 to 500 ml/min requires low flow accessories
Constant flow compensation
Provides constant flow within ± 5% for accurate air volumes
For both high and low flow applications
Eliminates the need for separate sampling pumps for high and low ranges when using optional low flow accessories
Minimum controls for easy operation
Two pumps in one easy-to-use sampler
RFI/EMI shielded and UL Listed for intrinsic safety
Case material and unique circuitry are designed to provide shielding from radio frequencies in the range of 27 to 1000 MHz, UL Listed for intrinsic safety for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C; CE marked; ATEX-approved model available
Highly accurate display
Digital time display tracks sample run time in minutes up to 99,999
Indicates low battery condition or flow fault without losing sample run time
Attempts auto-restart up to 5 times from flow fault
Low flow sampling capabilities
- All-in-One adjustable tube holder
- Multiple Adjustable Tube Holder with Constant Pressure Controller (CPC)
Multiple-tube sampling capabilities
Optional multiple adjustable tube holders used with a CPC allows up to four tube samples to be taken simultaneously, each at different flow rates. Saves time and uses fewer pumps
Full shift run times
Provides 12+ hours at 2000 ml/min, 25 inches water back pressure
Small, compact and lightweight
Weighs only 20 ounces (567 grams); measures 5 x 3 x 1.75 inches (12.7 x 7.6 x 4.4 cm)
Simple design, smooth surface
The impact-resistant case is easy to clean and decontaminate. Includes sturdy attached belt clip, detachable quick change battery pack, and built-in accessory mount
Built-in pulsation dampener
Built-in replaceable particulate trap
Quiet operation
Replacement parts in preassembled modules
Specifications
Performance Profile
Flow Range |
1000 to 3000 ml/min (5 to 500 ml/min requires All-in-One adjustable tube holder or Constant Pressure Controller [CPC] and Multiple Adjustable Tube Holder accessories)
|
Flow Control
|
Holds constant flow to ± 5% of set-point after calibration |
Compensation Range |
1000 ml/min up to 25 inches water back pressure 2000 ml/min up to 25 inches water back pressure 2500 ml/min up to 20 inches water back pressure 3000 ml/min up to 15 inches water back pressure |
Typical Back Pressure of Sampling Media (inches water)
Filter/Pore Size (µm) |
Flow Rate (L/min) |
1.0 |
1.5 |
2.0 |
2.5 |
25-mm MCE/0.8 |
6 |
9 |
12 |
15 |
25-mm MCE/0.45 |
14 |
22 |
28 |
35 |
37-mm MCE/0.8 |
2 |
3 |
4 |
5 |
37-mm PVC/5.0 |
1 |
1 |
2 |
2 |
Compare the information in this table to pump compensation range to determine appropriate applications.
|
Run Time |
NiCad Battery: 8 hrs minimum at above compensation ranges; dependent on media used. See Table 1. NiMH Battery: 12 hrs minimum at 2000 ml/min and up to 25 inches water back pressure; dependent on media used. See Table 2.
|
Power Supply |
Rechargeable 4.8-V nickel-metal hydride (NiMH) battery pack, 3.3-Ah capacity or Rechargeable 4.8-V nickel cadmium (NiCad) battery pack, 1.8-Ah capacity A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety. |
Battery Charging Time (varies with battery capacity and level of discharge) |
6 to 8.5 hrs using PowerFlex Charger |
Temperature |
Operating: 32 to 104 F (0 to 40 C) Storage: -4 to 113 F (-20 to 45 C) Charging: 50 to 113 F (10 to 45 C) |
Humidity |
0 to 95% non-condensing |
Flow Fault |
If pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault. During flow fault, the pump stops, the fault icon appears on the display, and elapsed time remains on the display. Auto-restart is attempted up to 5 times. Elapsed time information will be lost on restart.
|
Low Battery Fault |
LCD displays low battery icon and pump shuts down. LCD remains on. |
LCD Time Display |
LCD display shows elapsed pump run time in minutes up to 99,999. |
LCD Indicator |
LCD always remains on. Displayed elapsed run time information resets when pump is started. |
Noise Level |
62.5 dBA* - pump without case 55 dBA* - pump housed in noise-reducing case (optional accessory Cat. No. 224-96C)
* Pump operating at 2 L/min with a 37-mm, 0.8-µm MCE filter cassette measured at 3 ft (1 m) from pump |
RFI/EMI Shielding |
Complies with requirements of EN 55022 1987 Class B, and EN 50082-1:1992 Frequency range of radiated susceptibility test was 27 to 1000 MHz. CE marked |
Intrinsic Safety |
UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and, Class III, Temperature Code T3C. ATEX-approved models available; contact SKC |
Dimensions |
5 x 3 x 1.75 in (12.7 x 7.6 x 4.4 cm) |
Weight |
20 oz (567 gm) |
Multiple-tube Sampling |
Adjustable tube holder accessory allows user to take up to four simultaneous samples at flows from 5 to 500 ml/min. CPC required |
Tubing |
Requires 1/4-in ID tubing |
Protect sample pump from weather when in use outdoors.
Weather enclosures for outdoor pump use are available. Contact SKC.
Documentation
AirChek 52 Operating Instructions (PDF)
AirChek 52 Spec. Sheet (PDF)
Battery Pack for AirChek 52 Operating Instructions (PDF)
SDS for Nickel Cadmium Battery (PDF)
SDS for Nickel-metal Hydride Battery (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
UL Certificate of Intrinsic Safety
EC Declaration of Conformity (PDF)
EU Declaration of Conformity 224-51MTX, 224-52MTX Sidekick Pump (PDF)
EU Declaration of Conformity 224-50MH Sidekick Pump (PDF)
EU Declaration of Conformity 223-203A,-223A,-227A,-229A,-230A,-239A NiCD/NiMH Battery Chargers (PDF)
EU Declaration of Conformity 223-102A,-103A,-105A,-106A,-107A,-109A NiCD/NiMH Battery Chargers (PDF)
EU Declaration of Conformity 223-300B,-300C,-305B,-305C,-320B,-320C,-325B,-325C,-330B,-330C AC Adapter (Battery Eliminator) (PDF)
ATEX Certificate (PDF)
Chinese Language Operating Instructions AirChek 52 (PDF)
Pumps
AirChek 52 Sample Pump AirChek® 52 Pump only, with NiMH battery and screwdriver set, charger not included Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. |
224-52 |
AirChek 52 Sample Pump AirChek 52 Pump only, with screwdriver set, battery and charger not included Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit Note: For battery, see Cat. No. P78011AMH. |
224-52NB |
Kits
AirChek 52 Sample Pump Single Kit AirChek® 52 Single Pump Kit, with AirChek 52 pump, NiMH battery, screwdriver set, 100-240 V single charger, filter cassette holder, and carry case Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. |
224-52K |
AirChek 52 Sample Pump 5-pack Kit 5-pack AirChek® 52 Pump Kit, high flow sampling, with five each: AirChek 52 pumps with NiMH battery, screwdriver sets, filter cassette holders, one 5-station Multi-charger (100-240 V), and carry case Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. |
224-52K5 |
AirChek 52 Sample Pump Deluxe 5-pack Kit AirChek® 52 5-Pack Pump Kit, high and low flow sampling, with five each: AirChek 52 pumps with NiMH battery, screwdriver sets, filter cassette holders, constant pressure controllers, low flow holders with Type A tube covers, one 5-station Multi-charger (100-240 V), and carry case Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. |
224-52K5D |
AirChek 52 Sample Pump Single Kit AirChek® 52 Single Pump Kit, with AirChek 52 pump, NiMH battery, screwdriver set, 100-240 V single charger, filter cassette holder, and Pelican carry case Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. |
224-52KH |
AirChek 52 Sample Pump Starter Kit AirChek® 52 Pump Starter Kit, with NiMH battery, 100-240 V charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie Flow range: Constant flow 5 to 3000 ml/min Low flows from 5 to 500 ml/min require a low flow adapter kit. UL approved for intrinsic safety |
224-52-S |
Accessories
Low Flow Constant Pressure Controller (CPC) Low Flow Constant Pressure Controller (CPC), for AirChek 2000, AirChek 52, AirChek TOUCH, AirChek XR5000 and AirLite sample pumps; use CPC with a dual, tri, or quad Adjustable Low Flow Tube Holder |
224-26-CPC |
PowerFlex 5-station Battery Charger, 100-240 V PowerFlex® 5-station Battery Charger, 100-240 V, includes power supply and cord; for use with all SKC NiCad or NiMH battery powered air sampling pumps; purchase pump-specific cables separately from the following list: Cat. No. 223-1001 for AirChek 2000, Cat. No. 223-1002 for Universal (5-cell), Cat. No. 223-1003 for Universal (4-cell, MSHA), Cat. No. 223-1004 for AirChek 52, and Cat. No. 223-1005 for 222 Series Low Flow For U.S.-produced pump models only, not compatible with EX and ATEX-approved models |
223-1000 |
PowerFlex Cable, for AirChek 52 Series Pumps PowerFlex® Cable, for use with PowerFlex Single or Multi-chargers, for AirChek 52 Series air sampling pumps only |
223-1004 |
PowerFlex Single Battery Charger, 100-240 V PowerFlex® Single battery charger, 100-240 V, includes power supply and cord; purchase pump-specific cables(s) separately from the following list: Cat. No. 223-1001 for AirChek 2000, Cat. No. 223-1002 for Universal (5-cell), Cat. No. 223-1003 for Universal (4-cell, MSHA), Cat. No. 223-1004 for AirChek 52, and Cat. No. 223-1005 for 222 Series Low Flow For U.S.-produced pump models only, not compatible with EX and ATEX-approved models |
223-2000 |
Protective Nylon Pump Pouch, Black, for AirChek 52, 2000, and XR5000 Protective Nylon Pump Pouch, for AirChek XR5000 (high-power Li-Ion and alkaline battery models only), AirChek 2000, or AirChek 52 pump, black with adjustable waist belt and shoulder strap designed for worker comfort |
224-88 |
Protective Pouches, for AirChek 52, 2000, and XR5000 Pumps Noise-reducing Protective Nylon Pump Pouch, for AirChek 52, AirChek 2000, and high-power Li-Ion and alkaline AirChek XR5000 models, black, with shoulder and waist straps; reduces noise level from 62.5 to 55 dBA |
224-96C |
Pump Case, Deluxe, for 5-pack AirChek 2000, 52, or XR5000 Pump Kits 5-pack Pump Carry Case, Pelican, for AirChek 2000, AirChek 52, and AirChek XR5000 pumps; on wheels for easy transport, watertight, airtight, dustproof, and crushproof, equipped with foam for complete equipment protection; will accommodate five pumps and accessories. Case is larger than the Cat. No. 224-907 to accommodate more accessory items. |
224-910 |
Pump Kit Case, for 5-pack AirChek 2000, XR5000, and 52, 222 Series, and AirLite Pump Kits 5-pack Pump Carry Case, Pelican, for AirChek XR5000, AirChek 2000, AirChek 52, and AirLite pumps, on wheels for easy transport, watertight, airtight, dustproof, and crushproof, equipped with foam for complete equipment protection; will accommodate five pumps with accessories |
224-907 |
Replacement NiMH Battery Pack, for AirChek 52 Sample Pump Replacement NiMH Battery Pack, for AirChek 52 Sample Pump Replacement NiMH Battery Pack, for AirChek 52 Sample Pump |
P78011AMH |
Tygon Tubing Tygon Tubing Tygon Tubing, 1/4-inch ID x 3/8-inch OD,fits over impinger side arm, impinger inlet, filter cassette outlet, or Luer adapter. 50 feet |
225-1345 |