The Personal Environmental Monitor (PEM) is a small, lightweight inertial impaction sampler for measuring PM 10 or PM2.5 in indoor air. The PM2.5 and PM10 PEM models are each available in three flow rates (2, 4, and 10 L/min) to meet your applications. SKC recommends using the AirChek XR5000 Sample Pump with the 2 and 4 L/min PEMs and the Leland Legacy Sample Pump with the 10 L/min PEM.
Features
- Small and unobtrusive
- Can be connected to a personal sample pump and worn in the breathing
zone
- Referenced in EPA Method IP-10A
- For particles in indoor air
- Suitable for LEED Green Building sampling
Specifications
Performance Profile
Sample Time |
Varies |
Sample Rate |
2, 4, or 10 L/min |
Sample Pump |
Universal XR, AirChek Series, or Leland Legacy |
Sample Media |
37-mm PTFE filters ‡ |
Tubing |
3/16-inch ID |
Order
Description |
Cat. No. |
PEM Monitor, 10 µm, 2 L/min
Personal Environmental Monitor (PEM), for PM10 sampling, 10-µm cut-point at 2 L/min |
761-200 |
PEM Monitor, 10 µm, 4 L/min
Personal Environmental Monitor (PEM), for PM10 sampling, 10-µm cut-point at 4 L/min |
761-200A |
PEM Monitor, 10 µm, 10 L/min
Personal Environmental Monitor (PEM), for PM10 sampling, 10-µm cut-point at 10 L/min |
761-200B |
PEM Monitor, 2.5 µm, 2 L/min
Personal Environmental Monitor (PEM), for PM2.5 sampling, 2.5-µm cut-point at 2 L/min |
761-203 |
PEM Monitor, 2.5 µm, 4 L/min
Personal Environmental Monitor (PEM), for PM2.5 sampling, 2.5-µm cut-point at 4 L/min |
761-203A |
PEM Monitor, 2.5 µm, 10 L/min
Personal Environmental Monitor (PEM), for PM2.5 sampling, 2.5-µm cut-point at 10 L/min |
761-203B |
PEM Clamping Device
Clamping Device, for PEM Sampler, ensures that the nozzle cap is clamped parallel to the base and that the correct clamping force has been applied |
761-201 |
PEM Calibration Adapter
Calibration Adapter, for PEM sampling |
761-202 |
Accessories
Description |
Cat. No. |
AirChek XR5000 Sample Pump, High-power Li-Ion
AirChek® XR5000 Pump only, with high-power Li-Ion battery, charger not included Flow range: Constant flow 5 to 5000 ml/min Low flows from 5 to 500 ml/min require a low flow kit. UL approved for intrinsic safety |
210-5001 |
Leland Legacy Personal Sample Pump
Leland Legacy® Pump only (programmable) with Li-Ion battery (charger not included) Flow range: Constant flow 5 to 15 L/min CE marked to meet European CE Directive Not intrinsically safe |
100-3002 |
PTFE Filters, 2.0 µm, 37 mm
PTFE Filter with PMP support ring, 2.0 µm, 37 mm, no support pad included, pk/50 |
225-1709 |
Tygon Tubing
Tygon Tubing, 3/16-inch ID x 5/16-inch OD, 10 feet |
225-1346 |