The unique, patented SKC Parallel Particulate Impactor (PPI) Samplers are impaction-based and provide a precise match to ISO/CEN size-selection criteria. Respirable PPI Samplers match ACGIH and the ISO 7708/CEN criteria that is specified in the 2016 OSHA final rule on respirable crystalline silica. SKC PPI Samplers are offered in a choice of flow rates for maximum flexibility in pump options, sample duration, and contaminant concentration. PPI Samplers are available in disposable single-use plastic or reusable aluminum.
Features
- Collection efficiency precisely matches ISO 7708/CEN
criteria adopted in the OSHA final silica rule
- Resusable conductive aluminum
- Selection of flow rates available to meet specific applications
- 8 L/min respirable PPI: Enhances sensitivity (for short-term and/or low concentration sampling) using high flow pumps; ideal for new lower OSHA PEL for silica
- 4 L/min respirable PPI: Enhances sensitivity and can be used with personal pumps; TWA sampling for > 4 hours
- 2 L/min respirable PPI: 8-hour TWA sampling
- Patented disposable PPIs are
available pre-assembled with:
- Filter and pre-oiled substrates for chemical analysis
- Pre-oiled substrates
only – add your own weighed filter for
gravimetric analysis
- Performance published in Journal of Physics and referenced in the OSHA final silica rule
Specifications
Performance Profile
Sampling Rate |
2, 4, or 8 L/min |
Sample Pump |
AirChek Series for 2 and 4 L/min,
Leland Legacy for
8 L/min |
Sample Time |
Dependent on method used |
Sample Media |
37-mm, 5.0-µm PVC filter
Use cellulose pad or stainless steel screen for support.
|
Tubing |
1/4-in ID |
Impaction Substrate |
Four 3/8-in diameter pre-oiled porous plastic discs |
Analysis |
Gravimetric or chemical |
Body Material |
Conductive aluminum |
Dimensions |
Height: (clip to exhaust): 4.25 in
(10.8 cm)
Diameter: 1.8 in (4.6 cm)
Depth: 1.2 in (3.0 cm) |
Weight |
3.3 oz (93.6 gm) |
Order
Description |
Cat. No. |
Parallel Particle Impactor (PPI), Respirable, Aluminum, 2 L/min
Parallel Particle Impactor (PPI), aluminum, four stages, for respirable sampling at 2 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable or thoracic curves compared to any other sampler available. Requires substrates, filters, and supports purchased separately |
225-380 |
Parallel Particle Impactor (PPI), Respirable, Aluminum, 4 L/min
Parallel Particle Impactor (PPI), aluminum, four stages, for respirable sampling at 4 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable or thoracic curves compared to any other sampler available. Requires substrates, filters, and supports, which are purchased separately |
225-382 |
Parallel Particle Impactor (PPI), Respirable, Aluminum, 8 L/min
Parallel Particle Impactor (PPI), aluminum, four stages, for respirable sampling at 8 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable or thoracic curves compared to any other sampler available. Requires substrates, filters, and supports, which are purchased separately |
225-383 |
PPI Impaction Substrates, Porous Plastic, 3/8 inch
Impaction Substrates, 3/8-inch diameter porous plastic discs, pre-oiled, ready to use, disposable, for use with Parallel Particle Impactor (PPI), pk/200 Requires four discs for each sample |
225-388 |
Accessories
Description |
Cat. No. |
Leland Legacy Personal Sample Pump
Leland Legacy® Pump only (programmable) with Li-Ion battery (charger not included)
Flow range: Constant flow 5 to 15 L/min
CE marked to meet European CE Directive
Not intrinsically safe |
100-3002 |
AirChek XR5000 Sample Pump, High-power Li-Ion
AirChek® XR5000 Pump only, with high-power Li-Ion battery, charger not included
Flow range: Constant flow 5 to 5000 ml/min
Low flows from 5 to 500 ml/min require a low flow kit.
UL approved for intrinsic safety |
210-5001 |
Multi-purpose Calibration Jar
Multi-purpose Calibration Jar, 32-ounce polypropylene, contains a quick-screw cap and barbed fitting for easy use; allows for calibration of GS Cyclones, Reusable PPIs, and Low-volume PUF tubes. |
225-111 |
Tygon Tubing
Tygon Tubing, 1/4-inch ID x 3/8-inch OD,fits over impinger side arm, impinger inlet, filter cassette outlet, or Luer adapter. 50 feet |
225-1345 |
Stainless Steel Support Screen, 37 mm
Support Screen, 37 mm, stainless steel, wide mesh |
225-26 |
Cellulose Support Pad, pk/100
Support Pad, cellulose, 37 mm, pk/100 |
225-27 |
PPI Impaction Substrates, Porous Plastic, 3/8 inch
Impaction Substrates, 3/8-inch diameter porous plastic discs, pre-oiled, ready to use, disposable, for use with Parallel Particle Impactor (PPI), pk/200 Requires four discs for each sample |
225-388 |
PVC Filters, 5.0 µm, 37 mm
PVC Filter, 5.0 µm, 37 mm, no support pad included, GLA-5000, pk/100 |
225-5-37 |
Filter-Keeper, 37-mm, with Labels
Filter-Keeper, 37-mm filter storage and archiving system with labels, pk/100 |
225-8303 |
Filter-Keeper, 37 mm, with Labels
Filter-Keeper, 37-mm filter storage and archiving system with labels, pk/10 |
225-8303A |
Non-serrated Forceps, Stainless Steel
Forceps, stainless steel, non-serrated flat tips to prevent damage to filter membranes |
225-8371 |