The QuickTake® 30 air sampling pump offers constant flows from 10 to 30 L/min and run times up to 14 hours for sampling particulates. The pump is ideal for use with impactors, microvacuum cassettes, and spore traps.
The QuickTake 30 air sampling pump is not UL Listed for intrinsic safety.
Features
- 10 to 30 L/min constant flow sample pump
- Maintains set flow throughout a sampling period for complete sample integrity
- Ideal for use with BioStage viable cascade impactors, spore trap cassettes such as the VersaTrap, microvacuum cassettes, or other samplers that require flows up to 30 L/min
- Long run times on one Li-Ion battery charge
- AC charger/adapter for extended sampling
- Rechargeable lithium-ion battery pack
- Easy-to-use programmable timer for unattended sampling
- Select sample time presets or customize timer from 1 to 999 minutes
- Continuous run with manual shut-off
- Intermittent sampling
- Compact and portable
- 9.3 x 8.4 x 3.5 inches (23.6 x 21.3 x 8.9 cm)
- Weighs only 4.8 pounds (2.2 kg)
- Portable with easy-grip handle
- Optional mounting bracket for viable impactor
- Easy to use
- Large keypad control
- End-of-cycle visible and audible alarms
- Handy front-mounted intake for fast and simple media setup
- Fast setup
- High-contrast digital display
- Low noise
- Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min)
‡ |
Pump sampling at 10 L/min using 37-mm 0.8-µm MCE filter with new pumps and batteries. Pump performance may vary. See additional run times in Performance Profile. |
Specifications
Performance Profile
Flow Range
|
10 to 30 L/min |
Flow Compensation Accuracy
|
± 5% of set flow |
Compensating Flow Back Pressure Range
|
10 L/min at 90 inches water back pressure 20 L/min at 50 inches water back pressure 30 L/min at 15 inches water back pressure |
Typical Back Pressure of Sampling Media (inches water)
|
Flow Rate |
10.0
|
12.0
|
15.0
|
20.0
|
Filter/Pore Size (µm) |
|
25-mm MCE/0.8 |
65
|
80
|
103
|
148
|
25-mm MCE/0.45 |
138
|
172
|
> 200
|
—
|
37-mm MCE/0.8 |
22
|
28
|
36
|
51
|
37-mm PVC/5.0 |
9
|
11
|
15
|
21
|
Compare the information in this table to compensation range to determine appropriate applications. |
|
Power
|
Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 76.96 Wh, or battery with AC charger/adapter (100-240 V) |
Battery Recharge Time (varies with battery capacity and level of discharge)
|
Approximately 5 hrs with approved charger |
Typical Cumulative Run Time‡
|
Spore Trap cassettes (VersaTrap): 5 hrs at 15 L/min (battery only) BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only) 25-mm, 1.2-µm MCE filter: 9+ hrs at 10 L/min To achieve, use QuickTake 30 with a fully charged battery and AC charger/adapter. 37-mm, 0.8-µm MCE filter: 14+ hrs at 10 L/min (battery only)
Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times.
|
Temperature
|
Operating: 32 to 104 F (0 to 40 C) Storage: -4 to 95 F (-20 to 35 C) Charging: 32 to 113 F (0 to 45 C) |
Operating Humidity |
0 to 95% non-condensing |
Run Time Features
|
User-selectable features, user-adjustable presets. See Operating Instructions. Preset timed runs: 1, 2, 5, 10, or 15 min Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted) Intermittent sampling: User-set sample periods and sample delays. See Operating Instructions. |
Flow Fault Features
|
If the pump is unable to compensate due to excessive back pressure, the pump will go into flow fault mode. Flow fault features are enabled as the default setting. Flow fault may be disabled at the user’s option. See Operating Instructions. Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds. Fault restart: Pump attempts restart every 10 seconds up to five times. |
Media Compatibility
|
BioStage viable cascade impactors, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min |
Tubing
|
Requires 3/8-inch ID tubing |
Housing
|
ABS plastic |
Dimensions
|
8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm) |
Weight
|
4.8 lbs (2.2 kg) |
Noise Level |
Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min) |
‡ |
Results are obtained using a new pump and new fully charged battery. Pump and battery performance may vary. |
Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety.
Protect sample pump from weather when in use outdoors.
Pumps
QuickTake 30 Sample Pumps QuickTake 30 (with programmable timer) Sample Pump with Li-Ion battery pack and cassette/tubing adapter, charger not included Flow range: constant flow 10 to 30 L/min Ideal for use with BioStage® impactor, VersaTrap® cassettes, Air-O-Cell cassettes, WallCheck II, or impaction samplers that require flows to 30 L/min |
228-9530C |
Kits
QuickTake 30 Sample Pumps and Charger QuickTake 30 (with programmable timer) Sample Pump with Li-Ion battery pack, 110-240 V AC charger/adapter, and cassette/tubing adapter Flow range: constant flow 10 to 30 L/min Ideal for use with BioStage® impactor, BioCassette, Versa®Trap cassettes, Air-O-Cell cassettes, wall samplers, or impaction samplers that require flows to 30 L/min |
228-9530 |
QuickTake 30 Sample Pumps, Rotameter, and Charger QuickTake 30 (with programmable timer) Sample Pump with rotameter, Li-Ion battery pack, 110-240 V AC charger/adapter, cassette/tubing adapter and tubing Flow range: constant flow 10 to 30 L/min Ideal for use with BioStage® impactor, BioCassette, VersaTrap® cassettes, Air-O-Cell cassettes, wall samplers, or impaction samplers that require flows to 30 L/min |
228-9530A |
QuickTake 30 BioStage Pumps, Kit BioStage Pump Kit-DC, with QuickTake 30 (with programmable timer) Sample Pump with Li-Ion battery pack, 100-240 V AC charger/adapter, standard BioStage single-stage impactor, BioStage mounting bracket with inlet adapter, cassette/tubing adapters, rotameter, calibration adapter, and deluxe carry case Flow range: constant flow 10 to 30 L/min |
228-9530K |
Accessories
Case, for QuickTake 30 and Vacuum Pump Kits Heavy Duty Carry Case (toolbox style, not a Pelican case), for BioStage Pump Kit (with QuickTake 30) Cat. No. 228-9530K or BioStage Pump Kit (with vacuum pump) Cat. No. 225-9535K, measures 20 long x 9 wide x 13 inches high |
224-906 |
Replacement Battery Pack, Li-Ion, for QuickTake 30 Replacement Battery Pack, Li-Ion, for QuickTake 30 |
P75689 |
Rotameter, 3 to 30 L/min, for QuickTake 15/30 Rotameter, for use with QuickTake 15 or QuickTake 30 sample pump Range: 3 to 30 L/min |
320-100 |
Tygon Tubing Tygon Tubing, 3/8-inch ID, for QuickTake Series sampling pumps, 50 feet |
225-1352 |
VersaTrap Spore Trap Cassettes, pk/10 VersaTrap® Sampling Cassette, 37 mm, with microslide, for aerosol monitoring of mold spores, fibers, asbestos, and fungi; allows for quantitative analysis of biological and inorganic particles for most airborne aerosol screening applications; can be used with VersaTrap Wall Adapters to sample in wall cavities, pk/10 |
225-9820 |