HAZ-DUST 7204 Monitor Kit includes monitor, 37-mm 2-piece opaque filter cassette, open-faced sampling adapter, thoracic sampling inlet, IOM inhalable sampling head, flow adapter, zero accessory, battery charger, and DustComm, Pro Software
Features
- Flow compensated pump for compliance monitoring
- User-selectable flow rate
- Accepts any 37 or 25-mm preweighed, preloaded filter cassette for gravimetric samples
- Use filter samples to cross-calibrate to local dust
- Easy-to-clean miniaturized optical sensor mounts in the OSHA-defined breathing zone
- The only dust monitor that allows true size-selective sampling in the breathing zone
- Inhalable – 2 L/min with IOM (meets ISO 7708/CEN criteria) supplied with monitor
- Thoracic – 2 L/min with thoracic impactor, supplied with monitor
- Respirable – 2.75 L/min with GS-3 Cyclone (meets ISO 7708/CEN criteria)
- Create on-screen libraries of aerosol profiles and name data sets
- 22+ hours run time with Li-Ion battery
- Compact
- 4.75 x 3.5 x 2.25 inches (12.1x 8.9 x 5.7 cm)
- 1.12 lbs (0.51 kg)
- Wireless connectivity
- Large color touch display
- Real-time rolling graphs
- On-screen statistics
- 8-hour TWA, MIN, MAX, AVG
- Displays in g/m3 or mg/m3 (user selectable)
Specifications
Performance Profile
Sensors | Sensor Type: 90° light scattering 880nm
Calibration: Calibrated against Gravimetric reference NIST traceable- SAE fine test dust ISO12103-1 A2 Fine Test Dust.
Accuracy: +/- 10% to filter gravimetric SAE fine test dust
Precision: +/- 0.02 mg/m3
Sensing Range: 0.001-500 mg/m 3 or 1-500,000 µg/m3
PM Size Range: 0.1 to 100um
Minimum Resolution: 1 ug/m3 (0.001 mg/m3 )
Zero Stability: +/- 0.001 mg/m3 (give µg/m3 equivalent also) over 24 hours using 10 second log rate.
Humidity: 95% non-condensing
|
Display | 3.5”, 24-bit True color, Resistive Color Touch, with Auto Dimming |
Real-Time Data Display | Time: Hours, min., sec., 12hour & 24 hour
Date: MM/DD/YYYY, YY/MM/DD, DD/MM/YY Data Display: Concentrations (mg/m 3 , ug/m 3 ), Sampling Size Fraction of PM (OSHA TWA, AVE., MAX., MIN.), Start time, stop time, elapsed run time, Log rate, Flow, Real-Time Rolling Graphs (10 sec and 1 second), Personalized Named Data Sets, Unique Aerosol Profiles, Language Options, Battery Life Pump Faults, Flow Rate, In Feld Calibration Test, History of Data Sets
|
Sampling Flow Rate | Sampling Flow Rate:1-5 Lpm
The pump is capable to maintain flow within ±5% as follows: 1.0 Lpm up to 70 inch H2O; 2.5 Lpm up to 55 inch H2O, and 5.0 Lpm up to 20 inch H2O.
|
Filter Cassette | 37mm preloaded and weighted filter cassette
37mm 1um jeweled cassette for diesel particulates
25mm Preloaded cassette
|
|
Attachable Inlets |
Respirable Inlet | GS-3 Cyclone: 2.75 LPM for 4µm cut point (OSHA silica rule) Meets ISO 7708/CEN criteria
GS-1 Cyclone: 2.0LPM for 4µm cut point (OSHA silica rule) 3 LPM for 3.5 cut point (MSHA silica standard) 1.7 or 2.0 LPM with DPM cassette (MSHA DPM sampling) Meets ISO 7708/CEN criteria
|
Inhalable Inlet | IOM sampler: 2.0 LPM
Meets ISO 7708/CEN criteria
|
Thoracic Inlet | Thoracic Sampling Inlet: 2.0LPM |
Impactors | PM10, PM5.0, PM4.0, PM2.5 |
| |
Alarm Output | Audible & Visual
Audible: 90db at 3ft
Ceiling and S.T.E.L Alarms, Pump Fail, and Low Battery
|
Recording Time | 1 second to 15 days
Sampling Rate: 1 sec., 4 sec., 10 sec., and 60 sec
|
Data Storage | 43,200 data points |
Memory & Time Storage | >5 years |
Digital Output | Micro USB 6.00’ (1.83m), A Male to Micro B Male, 28SWG, Shielded |
Power Supply | Wall Mount, Multi Bald Included,
Voltage Input 100~240 VAC, Voltage Output 12V, Current Output 2A, CE, UL,CB, cUL, PSE, RCM
|
Battery | Lithium Ion pack, 7.4 Volt 3350 mAh, 24.79 watts |
Operating Time | 22+ hours Running at 2.0LPM with IOM and no filter. |
Operating & Storing Conditions | Operating Temperature: 0 to 50°C
Storage Temperature: -20 to 70°C
Operational Humidity: 0-95% Non-Condensing
|
DUSTCOMM Pro Software | Windows™ driven Windows 10 or greater |
Maintenance | Zero Calibration: Before each use
In Field Calibration Verification: Before each use
Flow Calibration: Before each use. Will automatically change when switching PM selective size.
Sensor Cleaning: By user when needed/ or during annual calibration
Factory Calibration: Annually or when instrument fails infield calibration verification.
|
Weight and Dimensions | Dimensions (Case): 3.5” x 2.25” x 4.75”
Sensor Dimensions: 1.75” x 1.5”
Weight Instrument: 1.14lbs
Weight Sensor: 0.6lbs
Display dimensions: 3.5”
|
PM Sensor | Sensor Type: 90° light scattering 88nm Calibrated against Gravimteric reference NIST traceable-SAE fine test dust ISO12103-1 A2 Fine Test Dust. |
Tripod Mounting | Optional Accessory |
Order
Description | Cat. No. |
HAZ-DUST 7204 Monitor Kit
HAZ-DUST 7204 Monitor Kit includes monitor, 37-mm 2-piece opaque filter cassette, open-faced sampling adapter, thoracic sampling inlet, IOM inhalable sampling head, flow adapter, zero accessory, battery charger, and DustComm, Pro Software
Requires calibration with equipment sold separately. See accessories.
| 770-7204 |
Accessories
Description | Cat. No. |
GS-3 Respirable Dust Cyclone, Conductive, 25 mm
GS-3 Respirable Dust Cyclone, 10 mm, with 25-mm cassette adapter, conductive plastic construction
| 225-103 |
HAZ-DUST 7204 Calibration Standard
HAZ-DUST 7204 Calibration Standard for Monitor, for verifying span and optical sensor performance | 770-327 |
HAZ-DUST IV Adapter, for GS-3 Cyclone, Post August 2007
HAZ-DUST IV Adapter, for GS-3 Respirable Dust Cyclone, required when using GS-3 Cyclone, for use with HAZ-DUST IV models manufactured after August 2007
EDC No. GSA-204
| 770-313 |
Multi-purpose Calibration Jar, Large
Multi-purpose Calibration Jar, allows for calibration of 8 inch long x 3.25-inch diameter devices
Multi-purpose Calibration Jar Operating Instructions (PDF)
| 225-112 |
PVC Filters, 5.0 µm, 37 mm
PVC Filter, 5.0 µm, 37 mm, no support pad included, GLA-5000, pk/100 | 225-5-37 |
Quartz Filters, 37 mm
Quartz (Tissuquartz) Filter, 432 µm thick, for sampling up to 1093 C, 37 mm, no support pad included, pk/25
| 225-1822 |
Accessories List:

225 103
|

770-313
|

225-112
|

225-5-37
|

225-1822
|
|
HOME
What is Air Sampling
Glossary
About Us
Product
Web Site Map